Home Educational Programs Curriculum & Lab Rates & Guidance Operator Reviews Field Guides About Contact
Inquire for Workshops
← Back to All Educational Programs
Specialized Training Module

Thermal Airflow Dynamics & Conductor Cooling Lab

Prevent Conductor Derating and Premature Hardware Failure via Thermal Management

Explore thermodynamic calculations, CFM static pressure matching, hot-aisle/cold-aisle containment, and how elevated ambient temperatures degrade electrical conductor ampacities.

Thermal Airflow Dynamics & Conductor Cooling Lab

Program Specifications

Format & Structure 2-Day Specialized Laboratory Session
Total Hours 16 Total Hours
Training Location Gimpo Thermal Wind Tunnel & Containment Facility
Tuition Basis KRW 950,000 per participant
Who This Course Is For

Target Audience & Prerequisites

Facility operators, HVAC technicians, and farm builders seeking to optimize heat rejection and prevent ambient-induced breaker tripping.

Recommended Prerequisites: Completion of High-Draw Power Infrastructure Workshop or equivalent basic electrical knowledge.
Key Competencies

Core Practical Outcomes

  • Calculate required cubic feet per minute (CFM) air changes based on total kilowatt heat dissipation.
  • Eliminate hot-air recirculation loops that push breaker ambient temperatures above 40°C.
  • Design negative pressure plenum chambers and exhaust louvers with minimal static backpressure.
  • Implement real-time sensor placement for inlet air monitoring and high-temp emergency cutoff.
Detailed Syllabus

Curriculum Modules & Bench Schedule

Step-by-step breakdown of classroom engineering lectures and practical hands-on laboratory exercises.

Day 1: Thermodynamics of Continuous Electrical Heat Generation

  • Converting electrical kW to BTU/hr (1 kW = 3,412 BTU/hr) and sensible heat ratios
  • CFM formula application: CFM = (kW × 3,160) / ΔT (°F)
  • Effects of ambient heat on copper resistivity and wire ampacity derating curves

Day 2: Physical Containment Design & Airflow Lab

  • Hot aisle vs cold aisle isolation principles in high-density rack configurations
  • Evaporative cooling pads, intake filtration, and static pressure drop analysis
  • Hands-on anemometer and smoke-pencil testing in the Gimpo airflow test chamber

What Is Included

  • + 16 hours of classroom and wind-tunnel laboratory exercises
  • + Airflow & CFM sizing engineering workbook
  • + Course certification credential

What Is Excluded

  • Custom facility CAD blueprint generation

Ready to Join This Workshop?

Contact our team to reserve a seat in the next scheduled lab cohort.

Submit Course Registration Inquiry Explore Full Curriculum & Lab Equipment